-40%

WZ5020L /WZ5012L DC Converter Step-down Adjustable Power Supply Module 12A/20A

$ 12.73

Availability: 47 in stock
  • Item must be returned within: 60 Days
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Brand: Unbranded
  • Display:: LCD
  • MPN: Does Not Apply
  • EAN: Does not apply
  • Module: CNC buck module
  • Return shipping will be paid by: Seller
  • Country/Region of Manufacture: China
  • UPC: Does not apply
  • Restocking Fee: No
  • Type: WZ5020L /WZ5012L
  • Condition: New

    Description

    Product Overview
    WZ5020L /WZ5012L DC Converter Step-down Adjustable Power Supply Module 12A/20A
    Cost-effective CNC adjustable step-down power module
    (DIY desktop CNC power supply can easily be done by yourself)
    1. Product highlights:
    1.1 LCD can display input/output voltage, output current/output power/output capacity/output time;
    1.2 CNC adjustment, precise and fast, step-down output, output voltage 0-50.00V arbitrarily adjusted, limit current 0-12.00A arbitrarily adjusted;
    1.3 The output end does not burn when it is poured backwards;
    1.4 The module can be set to turn on/off by default;
    1.5 has a variety of software protection mechanisms, and the protection threshold is adjustable. After the module's working parameters exceed the protection threshold, the output will be automatically turned off;
    1.6 Using synchronous rectification technology, high conversion efficiency: efficiency is above 90%;
    1.7 Enlarge the heat sink and install a fan to enhance heat dissipation.
    2. Product Parameters
    Model:WZ5012L
    Display:LCD
    Input Voltage Range:6-55.00V
    Input Voltage Resolution:0.01V
    Output Voltage Range:0-50.00V
    Output Voltage Resolution:0.01V
    Output Current Range:0-12.00A
    Output Current Resolution:0.01A
    Output Power Range:0-600.0W
    Input Voltage Accuracy:±(1%+5)
    Output Voltage Accuracy:±(0.3%+5)
    Output Current Accuracy:±(0.5%+5)
    Typical Value of Output Ripple:150mV
    Normal Operating Temperature Range:Peak value-10℃~40℃
    Capacity Measurement Range:0-999.9AH
    Statistical Error of Capacity Energy:±2%
    Statistical Time Range:0-100hour
    Depressurization Mode:differential  pressure>0.05%+1V
    The Weight of Nude:200g
    Including Packing:242g
    Product Size: panel 79X43X42mm
    Mainboard:106x76x40mm
    Model:
    WZ5020L
    Display:LCD
    Input Voltage Range:6-55.00V
    Input Voltage Resolution:0.01V
    Output Voltage Range:0-50.00V
    Output Voltage Resolution:0.01V
    Output Current Range:0-20.00A
    Output Current Resolution:0.01A
    Output Power Range:0-1000W
    Input Voltage Accuracy:±(1%+5)
    Output Voltage Accuracy:±(0.3%+5)
    Output Current Accuracy:±(0.5%+5)
    Typical Value of Output Ripple:150mV
    Normal Operating Temperature Range:Peak value-10℃~40℃
    Capacity Measurement Range:0-999.9AH
    Statistical Error of Capacity Energy:±2%
    Statistical Time Range:0-100hour
    Depressurization Mode:differential  pressure>0.05%+1V
    The Weight of Nude:200g
    Including Packing:242g
    Product Size: panel 79X43X42mm
    Mainboard:106x76x40mm
    Soft start: Yes
    Protection Mechanism:
    Input undervoltage protection (5.8-50V adjustable, default 5.8V)
    Output overvoltage protection (0-51.00V adjustable, default 51V)
    Output overcurrent protection (0-12.10A adjustable, default 12.10A)
    Timeout protection (0-100h adjustable, closed by default)
    Over-capacity protection (0-999.9Ah adjustable, closed by default)
    3.Key Description:
    Note:
    after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the
    protection code, and press any key to exit the protection interface.
    4. Interface Description:
    5. Method of use:
    5.1.
    Switch display parameters
    -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.
    5.2.
    Set output voltage
    -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
    5.3.
    Set constant current value
    (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
    5.4.
    Set the default on/off state of module power-on
    -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate encoder to switch two states.After setting, long press U/I to return to the normal interface.
    5.5.
    Setting of protection parameters on state and threshold
    -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection
    threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold
    .
    Short press rotate encoder to select which bit you want to set the protection parameter.Long press the rotary encoder to set the protection parameters on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection parameters are turned on by default.).Rotate the encoder left and right to make the parameters bigger and smaller.After setting, long press U/I to return to the normal interface.
    5.6.
    Calibration voltage and current
    -- press U/I button to enter the parameter setting interface under normal interface
    .
    Press SW key for a short time until the interface with zero appears, with zero + out + a symbol. Press and hold the rotary encoder to complete zero calibration. Short press SW button until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the encoder left and right to adjust the size of parameters.After the adjustment is completed, long press the rotary encoder to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface.
    Note:
    in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.
    6. Packing form:
    7. Cautions
    7.1.
    The module input positive in + and negative in - must not be reversed, and the module input in - must not be short circuited with the output out -, otherwise the module may be burnt out.
    7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
    7.3.
    This module is a step-down module, the input voltage should be higher than the output voltage, and a certain margin should be reserved. For full load output, the input voltage should be 55V.
    Shipping Policy
    Item Location
    Payment Mathord
    Returns Policy
    About Feedback
    Shipping Policy
    1. We Ship to Worldwide
    2. We ship your orders within 1-2 business days after the payment cleared.
    3. Item shipped from China via china Post Airmail, reach most of the countries within 2 to 4 weeks.
    4. Delivery time depends on destination and other factors, it may takes up to 20 days. If you don't receive
    the item after 25 days,please keep in touch with us, we'll investigate and solve the delivery problem.
    5. Import duties, taxes, and charges are not included in the item price or shipping cost. These charges
    are the buyer's responsibility. Please check with your country's customs office to determine what these
    additional costs will be prior to bidding or buying.
    Item Location
    ShenZhen
    Payment Mathord
    1. We accept PAYPAL only.
    2. Payment must be made within 7 days of auction closing (Unpaid dispute will automatically open when item
    is not paid in 7 days).
    3. PLEASE NOTE: SHIPPING&HANDING DOES NOT INCLUDE DUTIES, LOCATL TAXES OR ANY OTHER IMPORTATION FEES.
    4. Please list your special requests (color, packages, value of declaration, etc.) in the EBAY NOTES SECTION
    when you make payment
    Returns Policy
    1. Customer satisfaction is our top goal. All products are quality checked. They are new and in good
    condition when shipped to our customers. If product is defective or damage upon arrival, or wrong
    product shipped, please keep in touch with us immediately. Returns accepted within 14 days of delivery date
    and item must be in original new condition, not worn or altered in any way with attached tags & wrap.
    Otherwise deal is final. Return shipping must be paid by buyer.
    2. Please keep in touch with us first if you have anyproblems/questions/concerns. We will be happy to resolve
    any issues you may have in a cordial and friendly manner.
    3. We appreciate your Positive Feedback, and will do the same in return. PLEASE DO NOT leave
    negative feedback without first communication with us. Please allow max 24 HOURS for us to respond
    About Feedback
    We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is
    very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or
    negative feedback, so that we can satisfactorily address your concerns.It is impossible to address
    issues if we do not know about them!